GKRC type overvoltage and undervoltage monitoring relays are used to protect single-phase or three-phase systems from voltage fluctuations and phase-sequence faults.
Note: These relays have the function of switching off immediately when any phase exceeds (or decreases) 50% of the rated voltage.
DGRC type undervoltage monitoring relay is used to protect single-phase or three-phase systems from continuous operation when voltage fluctuations occur.
¡ñNon-flammable case
¡ñTrack Installation or Panel Installation
¡ñProtection Level: IP20
¡ñEnvironmental working temperature: 5¡æ, +50¡æ.
¡ñIEC 60255-3, IEC 60255-6, IEC 60870-5, IEC 60529

 
Product code
3- phase
Single-phase
Undervoltage
Overvoltage
Phase fault
Phase sequence fault
Interruption delay
Turn off delay
No zero line
Auxiliary power supply
DIN1 Track installation
DIN2 Track installation
Pieces / boxes
DGRC-01
¡ñ
¡ð
¡ñ
¡ñ
¡ñ
10
GKRC-01
¡ñ
¡ð
¡ñ
¡ñ
¡ñ
10
GKRC-02
¡ñ
¡ð
¡ð
¡ñ
¡ñ
¡ñ
10
GKRC-O2F
¡ñ
¡ð
¡ð
¡ñ
¡ñ
¡ñ
¡ñ
¡ñ
10
GKRC-02FA
¡ñ
¡ð
¡ð
¡ñ
¡ñ
¡ñ
¡ñ
¡ñ
¡ñ
10
GKRC-03
¡ñ
¡ð
¡ð
¡ñ
¡ñ
¡ñ
¡ñ
10
GKRC-03F
¡ñ
¡ð
¡ð
¡ñ
¡ñ
¡ñ
¡ñ
¡ñ
¡ñ
10
GKRC-M2
¡ñ
¡ð
¡ð
¡ñ
¡ñ
¡ñ
10
MCC-1D
5-15 min Turn off delay
¡ñ
¡ñ
¡ñ
¡ñ
¡ñ
10
MCC-3D
5-15 min Turn off delay
¡ñ
¡ñ
¡ñ
¡ñ
¡ñ
10
GKRC-20F
¡ñ
¡ñ
¡ñ
¡ñ
¡ñ
¡ñ
¡ñ
10

¡ð May close

Working principle
Relay connects directly to the network, and the required times/Overvoltage limit can be adjusted by a knob. If all 3-Phase monitors Voltage numbers. If any phase Voltage exceeds 1,5xUn, Relay closes without delay (within 500 Millisecond). If all are within the preset limit, output Relay opens. By adjustable delay tripping between 0, 1 and 10 seconds, it can be avoided that if any phase Voltage is lower than 0.5xUn, Relay has no delay closure (within 500 Millisecond). If the Voltage peak is straight when counting, the malfunction tripping operation is caused. If the phase Voltage of any monitoring exceeds the set value, the Voltage value returns to the preset limit before the start of the delay time and the delay time ends, and Relay continues to work normally.

Specifications
GKRC-02
GKRC -02F
GKRC -20F
GKRC -02FA
GKRC-03
GKRC-03F
GKRC-M2
GKRC-01
DGRC-01
MCC-1D
MCC-3D
Shell
size
PK28
PK22 DIN 1
PK28
PK22 DIN 1
weight
0,25kg/10Carton / boxes
0,1kg/10 Carton / boxes
0,25kg/10Carton / boxes
0,1kg/10
Carton / boxes
measure
Voltage
Undervoltage setting range
150-210V
(0,70-1,2)xUn
270-370V AC
150-210V
Overvoltage settin Range
240-300V
(0,8-1,30)xUn
410-510V AC
240-300V
Instant trip value
0,5xUn 1,5xUn
 
0,5xUn 1,5xUn
0,5xUn
168VAC
Instant trip time
100ms
lagging
3%
Power Supply
working voltage
230VAC¡À10%
230VAC,400VAC¡À30%
auxiliary Power Supply190-260V AC
400VAC¡À10%
230VAC¡À10%
working frequency
50/60 Hz
output /settin
Output contact
1CO 8A 2000VA cos§æ=1
1NO 8A 2000VA cos§æ=1
Delay time
0.1 -20s
environment condition
ambient temperature/ humidity
-5/ +55¡ãC ; 90%
Overvoltage category
III
Connect
install
Track installation;Screw terminal
line type
3-Phase£¬Zero line
3-Phase£¬Zero line
3-Phase£¬ No zero line
1 phase£¬Zero line
3-Phase£¬Zero line
1 phase£¬Zero line
3-Phase£¬Zero line
 
 



WEBSITE
PRODUCT
ENTES Electric Co., Ltd.

http://www.cnentes.com

International station£º
http://www.entes.com.tr
http://www.entes.org.cn

Add£º16th floor, first Shanghai plaza, 19 east gaolang road,Xinwu District,Wuxi City,Jiangsu Province,China
Contact£ºMiss Yu
Mobile£º018961828820
Tel£º086-0510-85026586
E-mail£º3370878344@qq.com
Copyright£ºENTES Electric Co., Ltd.