ENT.ERS Series
Summary

Long transmission lines, UPS, computers, lamps with electronic ballasts and energy-saving lamps increase the capacitance-to-energy ratio. Bypass reactor is used to compensate inductive power.
ENTS bypass reactor is designed to meet European standards, can withstand heavy working conditions and has a long service life. All reactors used to provide inductance power have CE mark. They are used as solutions in many areas, such as the location of heavily used UPS and electronic ballast loads, inductive load testing facilities and Telecommunications stations (such as television, radio, GSM). Technical characteristics
¡ñAir gap design to minimize shell grounding resistance.
¡ñHigh quality copper or aluminium winding, high permeability iron core.
¡ñComplying with EN610002-2 anti-harmonic load design standard
¡ñIntermediate coil thermal protection switch to prevent equipment overload and overheating
¡ñVacuum dipping process with low noise, minimizing heat loss and high mechanical properties
¡ñCE certification and compliance with EN 61558 2-20 standards

 
No shunt reactor
With shunt reactor
active power
100 kW
100 kW
Reactive power
40 kVAr
10 kVAr
Apparent power
107.7 kVA
100.5 kVA
power factor ratio
0.928
0.995

Single-phase shunt reactor

Model
kVAr
L
(mH)
Irms
(A)
working voltage
size
weight(kg)
ENT.ERS1 230/0.1
0.1
1661
0.44
230V 50Hz
1
1.3
ENT.ERS1 230/0.25
0.25
672
1.1
230V 50Hz
1
2
ENT.ERS1 230/0.5
0.5
338
2.17
230V 50Hz
2
3.5
ENT.ERS1 230/1
1
168
4.35
230V 50Hz
3
8
ENT.ERS1 230/1.5
1.5
103
6.82
230V 50Hz
4
10
ENT.ERS1 230/2.5
2.5
67
10.9
230V 50Hz
6
20
ENT.ERS1 230/0.3-0.4-0.5 (selectivity)
0.5
380
2.17
230V 50Hz
1
4.25

ENT.ERS series
Three-phase shunt reactor

Model
kVAr
L
(mH)
Irms
(A)
working voltage
size
weight(kg)
ENT.ERS3 400/0.25
0.25
2000
0.36
400V 50Hz
1
2
ENT.ERS3 400/0.5
0.5
1000
0.73
400V 50Hz
1
15
ENT.ERS3 400/1
1
505
1.45
400V 50Hz
1
3.7
ENT.ERS3 400/1.5
1.5
336
2.2
400V 50Hz
2
5
ENT.ERS3 400/2
2
252
2.9
400V 50Hz
3
9.5
ENT.ERS3 400/2.5
2.5
203
3.6
400V 50Hz
3
9.5
ENT.ERS3 400/3
3
168
4.35
400V 50Hz
4
10
ENT.ERS3 400/5
5
100
7.2
400V 50Hz
4
20
ENT.ERS3 400/7.5
7.5
68
10.9
400V 50Hz
5
26
ENT.ERS3 400/10
10
51
14.5
400V 50Hz
6
33.5
ENT.ERS3 400/15
15
34
21.74
400V 50Hz
6
54
ENT.ERS3 400/20
20
26
29
400V 50Hz
7
110
ENT.ERS3 400/25
25
20
36.3
400V 50Hz
7
115
ENT.ERS3 400/40
40
13
58
400V 50Hz
8
140
 
 



WEBSITE
PRODUCT
ENTES Electric Co., Ltd.

http://www.cnentes.com

International station£º
http://www.entes.com.tr
http://www.entes.org.cn

Add£º16th floor, first Shanghai plaza, 19 east gaolang road,Xinwu District,Wuxi City,Jiangsu Province,China
Contact£ºMiss Yu
Mobile£º018961828820
Tel£º086-0510-85026586
E-mail£º3370878344@qq.com
Copyright£ºENTES Electric Co., Ltd.